ELECTRICAL SYSTEM
DC GEN LIGHT ILLUMINATED
1. Generator switch - OFF, RESET, THEN ON.
2. Generator switch (no reset) - OFF.
3. Mission control switch - OVERRIDE.
4. Operating loadmeter - 100% MAXIMUM.
BOTH DC GEN LIGHTS ILLUMINATED
1. All nonessential equipment - OFF.
2. Land as soon as practicable.
EXCESSIVE LOADMETER INDICATION (OVER 100%)
1. Battery switch - OFF (MONITOR LOADMETER).
2. Loadmeter over 100% - NONESSENTIAL ELECTRICAL EQUIPMENT
OFF.
3. Loadmeter under 100% - BATT SWITCH ON.
INVERTER LIGHT ILLUMINATED
1. Affected AIRCRAFT INVERTER switch - OFF.
INST AC LIGHT ILLUMINATED
1. N1 and TGT indications - CHECK.
2. Other engine instruments - MONITOR.
CICRUIT BREAKER TRIPPED
1. BUS FEEDER breaker tripped - DO NOT RESET.
2. Nonessential circuit - DO NOT RESET.
3. Essential circuit - RESET ONCE.
E-13