TM 55-1510-219-CL
WING FIRE
1. Perform engine shutdown on affected side.
2. Land as soon as possible.
ELECTRICAL FIRE
1. Crew oxygen - 100%.
2. MASTER SWITCH - OFF.
3. All nonessential electrical equipment - OFF.
4. Battery switch - ON.
5. Generator switches (individually) - RESET, THEN ON.
6. Circuit breakers - CHECK FOR INDICATION OF DEFECTIVE CIRCUIT.
7. Essential electrical equipment - ON.
8. Land as soon as practicable.
SMOKE AND FUME ELIMINATION
1. Crew oxygen - 100% AND ON.
2. Bleed air valve switches - ENVIRO OFF.
3. Vent blower switch - AUTO.
4. Aft vent blower switch - OFF.
5. Cabin temperature mode switch - OFF.
6. If smoke and fumes are not eliminated, CABIN PRESS switch - DUMP.
7. Engine oil pressure - MONITOR.
E-11