TM 55-1510-215-MTF
C35. More than one inverter inoperative.
a.
Tripped inverter control circuit breakers.
b.
Defective INVERTER TEST switch.
c.
Defective wiring in inverter system.
C36. Battery charge light on annunciator panel inoperative.
a.
Defective light bulb.
b.
Connections on current detector loose or corroded.
c.
Defective current detector printed circuit board assembly.
C37. One portion of interior lighting or lighting control system
inoperative.
a.
Defective edge lighting.
b.
Defective components in overhead control panel.
c.
Defective lighting inverter.
C38. Fuel crossfeed valve inoperative or fuel fail light remains
illuminated.
a.
Defective auxiliary fuel pump.
b.
Defective crossfeed valve.
C39. Fuel transfer pump inoperative.
a.
Defective transfer pump relay.
b.
Defective transfer switch in fuel management panel.
c.
Defective fuel transfer pressure switch.
3-16