TM 55-1510-215-MTF
C30. Stall warning system inoperative. (Battery switch either
position.)
a.
Defective stall warning switch.
b.
Defective stall warning horn.
c.
Defective wiring.
C31. Stall warning system inoperative with battery switch in off
position (operative with battery switch in ON position).
a.
Tripped stall warning safety circuit breaker.
C32. Stall warning horn sounds continuously.
a.
Defective stall warning switch.
b.
Defective wiring.
C33. Stall warning disable switch inoperative.
a.
Defective stall warning disable switch.
b.
Defective wiring.
C34. One inverter inoperative.
a.
Tripped inverter control circuit breaker.
b.
Tripped generator fault circuit breaker.
c.
Defective current limiter.
d.
Defective inverter.
e.
Defective inverter power relay.
f.
Loose ground connection.
g.
Defective wiring to inverter.
h.
Defective INVERTER TEST switch.
3-15