TM 10-6640-216-13&P
4-21. REMOVE/INSTALL WALL SWITCHES - continued.
INSTALLATION
1.
Install ice maker wall switch. See figure 4-12.
a.
Connect wires to new switch and tighten three terminal screws. Remove tags.
b.
Guide new switch into junction box. Be sure wires are not kinked or strained.
c.
Install two switch mounting screws.
d.
Place cover plate on junction box, install two cover plate screws.
2.
Install vat-air/water pump switch. See figure 4-12.
a.
Connect wires and tighten three terminal screws.
b.
Guide new switch into junction box. Be sure wires are not kinked or strained.
c.
Place cover on switches and install two switch mounting screws.
d.
Place cover plate on junction box. Install two cover plate screws.
3.
Install light/blackout override switch. See figure 4-13.
a.
Connect wires to new switch and tighten three terminal screws. Remove tags.
b.
Guide new switch into junction box. Be sure wires are not kinked or strained.
c.
Install two switch mounting screws.
d.
Place cover plate on junction box. Install six cover plate screws.
4.
Turn an electrical power.
a.
Close appropriate circuit breaker.
b.
Turn the new switch to the on position and verify proper operation.
4-54