4-18. REMOVE/INSTALL BLOWER ASSEMBLY.
This task covers:
a. Removal
b. Installation
INITIAL SET-UP
Tools Required
General Mechanics Tool Kit, Appendix B, Item 1
General Safetv Instructions
WARNING
ELECTRICAL SHOCK
Before performing any maintenance actions on electrical equipment
ensure all electrical power has been turned off. Death or serious
injury may occur from failure to do this.
REMOVAL
Remove blower motor. See figure 4-9.
a.
Set the BLOWER switch next to entrance door to the off position.
b.
Lift blower cover up.
c.
Unplug blower electrically from electrical outlet.
d.
Remove six mounting screws, lockwashers and flat washers.
e.
Remove motor from storage cabinet.
f.
Remove plug from blower motor power cord.
INSTALLATION
1.
Install blower motor. See figure 4-9.
a.
Install plug on cord of new blower motor.
b.
Align new motor to mounting plate. Install six mounting plate screws, lockwashers and
flat washers.
c.
Plug in blower electrically at electrical outlet.
d.
Lower cover over blower.
e.
Set the blower motor switch to the on position and verify proper operation.
4-41