TM 10-6640-216-13&P
4-17. REMOVE/INSTALL ECU DAMPER ASSEMBLY - continued.
ASSEMBLY
Install motor bracket and motor in damper mechanism. See figure 4-8.
a.
Install new motor bracket by fastening bracket to new damper mechanism with two
screws, flat washers, lockwashers, and nuts.
b.
Tighten bracket mounting screws and nuts.
c.
Attach new motor to motor bracket with two screws, flat washers, and lockwashers.
d.
Tighten motor mounting screws and nuts.
e.
Attach motor linkage to motor by snapping in place.
f.
Tighten setscrew.
INSTALLATION
Install the ECU damper assembly. See figure 4-8.
a.
Insert damper assembly with motor attached into plenum and attach with four screws,
eight flat washers, and four nuts.
b.
Tighten screws and nuts.
c.
Install plenum using eight screws, Iockwasher and flat washers.
d.
Install purge port damper assembly. (Paragraph 4-16).
e.
Connect motor electrically and remove tags.
f.
Restore power to the laboratory and run an operational test of the purge system.
4-40