TM 10-6640-216-13&P
3-9. REMOVE/INSTALL WATER DEMINERALIZE CARTRIDGE.
This task consists of:
a. Removal
b. Service
c. Installation
INITIAL SET-UP:
Tools Required
Cross-Tip Screwdriver, Appendix C, Item 7
General Safety Instructions
WARNING
Resins contained in the water demineralize cartridges will cause eye
irritation. In case of eye contact, flush eyes with water for at least
fifteen minutes and contact a physician. Failure to comply with this
warning could result in serious eye damage. Refer to material for
safety data sheet.
NOTE
Procedures apply to both cartridges. Always replace cartridges as a
set.
REMOVAL
Remove Water Demineralize Cartridge. (Figure 3-6).
a.
Be sure the water valve is closed.
b.
Disconnect rubber tubing from the top and bottom of the cartridge by hand pull pressure.
c.
Remove defective cartridge.
INSTALLATION
Install Water Demineralize Cartridge. (Figure 3-6).
NOTE
Left cartridge is mixed BED DI. Right Cartridge is organic removal.
a.
Place new cartridge with flow arrow pointing up into cartridge retainer on roadside wall
above sink.
b.
Connect rubber tubing on the top and bottom of the cartridge.
3-23