TM 10-6640-216-13&P
3-6. REMOVE/INSTALL ECU PLENUM INTAKE FILTER.
This task consists of:
a. Removal
b. Cleaning
b. Installation
INITIAL SET-UP
Materials/Parts
Detergent, Appendix E, Item 8
Equipment Conditions
ECUs turned off.
General Safety Instructions
WARNING
Compressed air used for cleaning should not exceed 30 psi (3.5
Kg/cm2). Do not direct compressed air against skin. Use goggles or
full face shield.
REMOVAL
Remove ECU Plenum Intake Filter. (Figure 3-3).
Grasp filter firmly and slide from bracket.
CLEANING
WARNING
Compressed air used for cleaning should not exceed 30 psi (3.5
Kg/cm2). Do not direct compressed air against skin. Use goggles or
full face shield.
Clean ECU plenum intake filter.
Clean filter by washing in soapy water and blowing dry with low pressure air.
INSTALLATION
Install ECU Plenum Intake Filter. (Figure 3-3).
Install filter by sliding into retaining bracket.
3-16