TM 1-1510-224-MTF
C21.
Landing gear pump motor operating longer than 14 seconds
in the extended mode, but the 2-ampere circuit breaker does
not trip.
Downlock switches failing to open and/or the time delay PCB is faulty.
C22.
Landing gear HYD FLUID LOW light not functioning.
a.
Defective lamp.
b.
Defective fluid indicator circuit.
C23.
Landing gear circuit breaker trips.
Shorted circuit.
C24.
Landing  gear  warning  horn  inoperative  when  LDG  GEAR
CONTR switch is in the up position and weight of aircraft is
on struts, but operates when a POWER lever is closed and
the gear is retracted.
a.
Poor ground at landing gear control switch.
b.
Defective  wiring  between  LDG  GEAR  CONTR  switch  and
landing gear safety switch.
c.
Defective stall/landing gear warning module.
d.
Defective speaker.
C25.
Landing  gear  warning  horn  inoperative  when  POWER  lever
is closed and landing gear is up.
a.
Defective or out of adjustment POWER lever switch.
b.
Defective    wiring    between    POWER    lever    switches    and
pedestal  terminal  board,  and  between  LDG  GEAR  CONTR
switch and stall/landing gear warning horn module.
c.
Defective Q switch.
d.
Defective speaker.
C26.
Landing  gear  warning  horn  fails  to  shut  off  when  landing
gear is extended.
Defective or out of adjustment down-lock switches.
3-10