TM 1-1510-224-MTF
b.
LANDING   GEAR   POWER   circuit   breaker   (under   floor   in
cabin) tripped.
c.
Landing   gear   power   safety   control   circuit   breaker   (under
floor in cabin) tripped.
d.
Landing   gear   power   sense   circuit   breaker   (under   floor   in
cabin) tripped.
e.
Landing   gear   safety   power   circuit   breaker   (under   floor   in
cabin) tripped.
f.
Faulty power pack motor.
g.
Faulty power relay.
h.
Faulty  remote-controlled  circuit  breaker  (RCCB)  (under  floor
in cabin).
i.
Defective landing gear control switch.
j.
Defective wiring.
C14.
Landing gear fails to retract.
a.
Safety switch not closing.
b.
Pressure switch not closing.
c.
Gear selector valve stuck.
d.
Circuit  is  open  between  the  selector  valve  and  the  power
relay.
e.
Time delay circuit opening prematurely.
f.
Hand pump handle improperly stowed.
g.
Service valve in up position.
h.
Defective landing gear control switch.
i.
Defective wiring.
C15.
Landing gear fails to extend.
a.
Service valve switches faulty.
b.
Landing gear selector valve stuck in up position.
c.
Control  switch  not  providing  power  to  the   extend   side   of
selector valve.
d.
Defective limit switch.
e.
Defective landing gear control switch.
3-8