TM 1-1510-218-CL
E-12
6. Fuel quantity Monitor.
NAC LOW LIGHT ILLUMINATED
1. Usable fuel remaining Confirm.
2. Land as soon as possible.
ELECTRICAL SYSTEM EMERGENCIES
DC GEN LIGHT ILLUMINATED
1. GEN switch OFF, RESET, then ON.
IF THE GENERATOR DOES NOT RESET:
2. GEN switch (no reset) OFF.
3. Operating loadmeter 100% maximum.
BOTH DC GEN LIGHTS ILLUMINATED
1. All nonessential equipment Off.
2. Land as soon as practicable.
EXCESSIVE
LOADMETER
INDICATION
(OVER 100%)
1. Loadmeter Monitor.
2. BATT switch OFF (monitor loadmeter).
IF LOADMETER STILL INDICATES ABOVE 100%:
3. Nonessential electrical equipment off.
IF LOADMETER INDICATES 100% OR BELOW:
4. BATT switch ON.