TM 1-1510-218-CL
E-10
ELECTRICAL FIRE
1. Crew oxygen masks As required.
2. Passenger oxygen As required.
3. MASTER SWITCH OFF. (Visual conditions
only).
4. AII nonessential electrical equipment OFF.
5. BATT switch ON.
6. Generator switches (individually) RESET, then
ON.
7. Circuit breakers Check for indication of defective
circuit.
8. Essential electrical equipment ON (individually
until fire source is isolated).
9. Land as soon as practicable.
SMOKE AND FUME ELIMINATION
1. Crew oxygen masks 100% and on.
2. Passenger oxygen ON.
3. BLEED AIR VALVE switches ENVIRO OFF.
4. VENT BLOWER switch AUTO.
5. AFT VENT BLOWER switch OFF.
6. CABIN AIR/TEMP MODE switch OFF.
7. If smoke and fumes are not eliminated, CABIN
PRESS switch DUMP.
8. Passenger oxygen masks Check. Confirm that
all
passengers
are
receiving
supplemental
oxygen.
9. Engine oil pressure Monitor.