TM 55-4920-401-13&P
Indicator
P a r a m e t er
T e m p e r a t u re
100
3000
100
3000
Table 4-13. Indicator Data Table.
Period
Reference Period
S t a t e s
Counter State
F i n i sh
+ Out-of-Range
4000
1400
I
Preamp Output
for Full-Scale
I n p u t s
8.44 vdc (+ 0.4 vdc)
at 1399° C. Measure
at test point 4 in
figure 4-8.
7.16 vdc (+ 0.72 vdc)
at 199.9% rpm.
Measure at test
point 25 in figure 4-9.
Preamp Output
for Zero
Reading
0 + 0.04 vdc
0 + 0.04 vdc
4-22