TM 55-4920-401-13&PTable 4-10. Resistance Check Circuit Troubleshooting Table.MalfunctionCorrective ActionR E S I S T A N C E C H E C K m e t e rcannot be zeroed.R E S I S T A N C E C H E C K m e t e rd o e s n o t d e f l e c t w h e n R E -S I S T A N C E & A / C I N D I C A T ORCHECK switch is in any position.RESISTANCE CHECK meter de-flects in full clockwise direction ina l l r e s i s t a n c e p o s i t i o n s o f R E-S I S T A N C E & A / C I N D I C A T ORCHECK switch.Probable Causea .D e f e c t i v e R E -SISTANCE CHECK metera.D e f e c t i v e R E -SISTANCE CHECK meterb. Defective FUNCTIONSELECT switchc. Defective BAL po-t e n t i o m e t e r ( R 2 ) o n r e-s i s t a n c e a n d i n s u l a t i oncheck boarda. Defective resistancecheck adapterb. Defective instrumentcablec. Resistor R3 open on re-s i s t a n c e a n d i n s u l a t i oncheck board.d. Defective FUNCTIONSELECT switcha. Replace meter (34, figureFO-8).a. Replace meter (34, figureFO-8).b. Replace switch 32, figure(4-37).c. Replace potentiometer (7,figure 4-38).a. Repair or replace adapterb. Repair or replace cable.c. Replace resistor (1, fig-ure 4-38).d. Replace switch (32, figure 4-37).4-12