TM 55-1510-219-MTF
PROCEDURE
TROUBLESHOOTING
REFERENCE
(4) Carrier rod - Check orange indicator
aligned with orange stripe on carrier
rod. (Observe through window, aft
lower corner.)
c. Battery switch - OFF.
d. Cargo door - Check closed and latched.
e. Cabin door - Close but leave unlatched.
Check CABIN DOOR annunciator light
illuminated.
f. Cabin door - Open. Check CABIN DOOR
annunciator light extinguished.
g. Battery switch - ON. Check CABIN
DOOR annunciator light illuminated.
h. Cabin door - Close and latch. Check
CABIN
DOOR
annunciator
light
extinguished.
i. Battery switch - OFF.
NOTE
The above procedures check both cargo and cabin door
security provisions.
*3. Emergency exit - Check secure and key
removed.
*4. Mission cooling ducts - Check open and free
of obstructions.
5. Crew briefing - As required.
2-7