TM 55-1510-219-10
3.
Ignition and engine start switch-ON.
Propeller should begin to rotate and
associated
IGN
ON
light
should
illuminate. Associated FUEL PRESS light
should extinguish.
4.
Condition lever (after N1 RPM stabilizes,
12% minimum)-LOW IDLE.
CAUTION
Monitor TGT to avoid a hot start.
If there is a rapid rise in TGT, be
prepared to abort the start before
limits are exceeded. During
starting, the maximum allowable
TGT is 1000°C for five seconds. If
this limit is exceeded, use ABORT
START
procedure
and
discontinue start. Enter the peak
temperature and duration on DA
Form 2408-13.
5.
TGT
and
N1-Monitor
(TGT
1000°C
maximum, N1 52% minimum).
6.
Oil pressure-Check (60 PSI minimum).
7.
Ignition and engine start switch-OFF after
TGT stabilized.
8.
Condition lever-HIGH IDLE. Monitor
TGT as the condition lever is advanced.
9.
Generator switch-RESET, then ON.
8-24. SECOND ENGINE START (BATTERY START).
1.
First engine generator load-50% or less.
2.
Ignition and engine start switch-ON.
Propeller should begin to rotate and
associated IGN on light should illuminate.
Associated FUEL PRESS light should
extinguish.
3.
Condition lever (after N1 RPM passes
12% minimum)-LOW IDLE.
CAUTION
Monitor TGT to avoid a hot start.
If there is a rapid rise in TGT, be
prepared to abort the start before
limits are exceeded. During
starting, the maximum allowable
TGT is 10000C for five seconds. If
this limit is exceeded, use ABORT
START
procedure
and
discontinue start. Enter the peak
temperature and duration on DA
Form 2408-13.
4.
TGT
and
N1-Monitor
(TGT
1000IC
maximum, N1 52% minimum).
5.
Oil pressure-Check (60 PSI minimum).
6.
Ignition and engine start switch-OFF after
TGT stabilized.
7.
Battery charge light-ON.
8.
Second engine generator-RESET, then
ON.
9.
Inverter switches-ON, check INVERTER
lights OFF.
10.
Condition levers-As required.
8-25. ABORT START.
1.
Condition lever-FUEL CUTOFF.
2.
Ignition and engine start switch-STARTER
ONLY.
3.
TGT-Monitor for drop in temperature.
4.
Ignition and engine start switch-OFF.
8-26. ENGINE CLEARING.
1.
Condition lever-FUEL CUTOFF.
2.
Ignition and engine start switch-OFF (1
minute minimum).
CAUTION
Do not exceed starter limitation of
30 seconds ON and 5 minutes
OFF for two starting attempts and
engine clearing procedure. Allow
30 minutes off before additional
starter operation.
3.
Ignition and engine start switch-STARTER
ONLY (15 seconds minimum, 30 seconds
maximum).
4.
Ignition and engine start switch-OFF.
8-27. FIRST ENGINE START (GPU START).
1.
INS-As required.
CAUTION
Mission control switch should be
OFF prior to start.
8-13