TM 1-1510-233-CL
P-26
ANTI-ICE AND DEICE SYSTEMS
1.
WINDSHIELD anti-ice switches (2) NOR-
MAL then HIGH. Check PILOT and COPILOT
(individually) for loadmeter rise, then OFF.
2.
AUTO PROP anti-ice switch ON (momen-
tarily). Check for PROP AMP meter shows in-
dication and the overhead DC % LOAD meter
shows a rise.
3.
MANUAL PROP anti-ice switch ON (mo-
mentarily). Check for loadmeter rise.
4.
SURFACE deice switch SINGLE CYCLE
AUTO. Check for drop in pneumatic pressure
and wing deice boot inflation, and after 6 sec-
onds for a second drop in pressure.
5.
SURFACE deice switch MANUAL. Check
that surface boots inflate and remain inflated
while switch is held in MANUAL. Release
switch and check that the boots deflate.
6.
ANTENNA deice switch SINGLE CYCLE
AUTO. Check for a drop in pneumatic pressure
and antenna deice boot inflation.
7.
ANTENNA deice switch MANUAL. Check
that boots inflated, and remain inflated, then
OFF.
8.
RADOME anti-ice switch ON. Check for
loadmeter rise and pneumatic pressure drop,
then off.
PNEUMATICS/VACUUM/PRESSURIZATION
1.
PNEUMATIC PRESSURE gage/GYRO SUC-
TION gage Check in green arcs.
2.
CABIN ALT controller Set a minimum of 500
feet lower than field pressure altitude.