TM 1-1510-233-CL
P-2
5.
FIRE PULL handles In.
6.
#1 and #2 FUEL PRESS warning annunciators
Extinguished.
7.
STANDBY fuel pump switches STANDBY
PUMP.
8.
#1 and #2 FUEL PRESS warning annunciators
Illuminated.
9.
Crossfeed Check system operation by acti-
vating switch momentarily left then right, not-
ing that #1 and #2 FUEL PRESS warning an-
nunciators extinguish and that the FUEL
CROSSFEED advisory light illuminates as
switch is energized.
ENGINE FIRE PROTECTION SYSTEM
1.
ENG FIRE TEST switches Hold switches to
DET position, check that FIRE PULL handle
warning annunciators, and MASTER WARN-
ING annunciators illuminate.
2.
ENG FIRE TEST switches Hold switches to
EXT position, check that SQUIB OK and
EXTGH DISH annunciators, and MASTER
CAUTION annunciators illuminate.
NOTE
If MASTER WARNING is cancelled be-
tween tests, it may not re-illuminate.
STALL AND GEAR WARNING SYSTEM
1.
STALL WARN TEST switch TEST. Check
that warning horn sounds.
2.
LDG GEAR WARN TEST switch TEST.
Check that warning horn sounds and that the
LDG GEAR CONTR handle warning lights illu-
minate.