ELECTRICAL SYSTEM EMERGENCIES
DC GEN ANNUNCIATOR ILLUMINATED
1.GENERATOR switch OFF, RESET, then
ON.
2. GENERATOR switch (no reset) Off.
3. MISSION CONTROL switch ORIDE.
4. Operating loadmeter 100% maximum.
BOTH DC GEN ANNUNCIATOR ILLUMINATED
(RESET FAILED)
1. All nonessential equipment Off.
2. Land as soon as practicable.
EXCESSIVE
LOADMETER
INDICATION
(OVER 100%)
1. BATTERY switch OFF (monitor loadmeter).
2.Loadmeter over 100% Nonessential
electrical equipment off.
3.Loadmeter under 100% BATTERY switch
ON.
INVERTER ANNUNCIATOR ILLUMINATED
1. Affected INVERTER switch Off.