TM 1-1510-218-CL
E-14
LANDING EMERGENCIES
LANDING GEAR UNSAFE INDICATION
1. LDG GEAR CONTROL switch Check DN.
2. LANDING GEAR CONTROL and
LANDING
GEAR IND circuit breakers Check in.
3. GEAR DOWN lights illuminated Check.
IF INDICATOR REMAINS UNSAFE:
4. Landing gear emergency extension Perform.
LANDING GEAR EMERGENCY EXTENSION
1. Airspeed Below 181 KIAS.
2. LANDING GEAR CONTR circuit breaker Pull.
3. LDG GEAR CONTROL switch DN.
4. Alternate extension lever Unstow.
5. Alternate extension lever Pump up and down
until the three green
GEAR DOWN lights
illuminate or resistance is felt.
6. Alternate extension lever As required.
GEAR-UP
LANDING
(GEAR
UP
OR
UNLOCKED)
1. Fuel load Reduce.
2. Personnel emergency briefing Completed.
3. Loose equipment Stowed.
4. BLEED AIR VALVES ENVIRO OFF.
5. CABIN PRESS switch DUMP.