TM 1-1510-218-CL
N-4
SECOND ENGINE START (BATTERY
START)
1. First engine generator load 50% or less GEN
switch OFF.
2. Propeller area Clear.
3. Engine Start.
4. Engine and systems instruments Check.
5. BATTERY CHARGE light on Check.
6. INVERTER switches ON, check, INVERTER
lights OFF.
7. Second engine GEN switch RESET, then ON.
8. CONDITION levers As required.
9. Red anticollision light Reset.
ABORT START
1. CONDITION lever FUEL CUTOFF.
2. IGNITION AND ENGINE STARTER switch
STARTER ONLY.
3. ITT/TGT Monitor for drop in temperature.
4. IGNITION AND ENGINE START switch OFF.
ENGINE CLEARING
1. CONDITION lever FUEL CUTOFF.
2. IGNITION AND ENGINE START switch OFF
(1-minute minimum).
3. IGNITION AND ENGINE START
switch
STARTER
ONLY
(15
seconds
minimum,