TM 1-1510-218-10
8-12
CAUTION
If
ignition
does
not
occur
within
10 seconds after moving condition lever to
LOW
IDLE,
initiate
Engine
Clearing
procedure, Paragraph 8-25. If for any
reason a starting attempt is discontinued,
the entire starting sequence must be
repeated after allowing the engine to come
to a complete stop (1-minute minimum).
b. CONDITION
lever
(After
N1,
RPM
stabilizes above 12% for 5 seconds
minimum) LOW IDLE.
CAUTION
Monitor TGT to avoid a hot start. If there is
a rapid rise in TGT, be prepared to abort
the start before limits are exceeded.
During
engine
start,
the
maximum
allowable TGT is 1000 °C for 5 seconds. If
this limit is exceeded, use Abort Start
procedure,
Paragraph
8-24,
and
discontinue
start.
Record
peak
temperature on DD Form 2408-13-1.
c. TGT and N1 Monitor (TGT 1000°C
maximum, N1 52% minimum).
d. Oil pressure Check (60 psi minimum).
e. IGNITION AND ENGINE STARTER
switch OFF.
4. Engine and systems instruments Check.
5. CONDITION lever HIGH IDLE. Monitor
TGT as the condition lever is advanced.
NOTE
After starting the first engine with a GPU,
the second engine is normally started
using a battery start. If a GPU start is
required or desired for the second engine
start, use the Second Engine Start (GPU
Start)
procedure,
Paragraph
8-27.
Otherwise, use the Second Engine Start
(Battery Start) procedure, Paragraph 8-23.
6. GPU disconnect As required. Disconnect
if second engine start is to be a battery
start.
CAUTION
Do not turn on generators with GPU
connected.
7. GEN switch RESET, then ON.
*
8-27. SECOND ENGINE START (GPU START).
1. Propeller area Clear.
2. Engine Start.
a. IGNITION AND ENGINE STARTER
switch ON. IGN ON light should
illuminate and associated FUEL PRESS
light should extinguish.
CAUTION
If
ignition
does
not
occur
within
10 seconds after moving condition lever to
LOW
IDLE,
initiate
Engine
Clearing
procedure, Paragraph 8-25. If for any
reason a starting attempt is discontinued,
the entire starting sequence must be
repeated after allowing the engine to come
to a complete stop (1-minute minimum).
b. CONDITION
lever
(after
N1
RPM
stabilizes, above 12% for 5 seconds
minimum) LOW IDLE.
CAUTION
Monitor TGT to avoid a hot start. If there is
a rapid rise in TGT, be prepared to abort
the start before limits are exceeded.
During
engine
start,
the
maximum
allowable TGT is 1000 °C for 5 seconds. If
this limit is exceeded, use Abort Start
procedure, Paragraph 8-24, to discontinue
start. Record the peak temperature and
duration on DA Form 2408-13-1.
c. TGT and N1. Monitor (TGT 1000 °C
maximum N1 52% minimum).
d. Oil pressure Check (60 psi minimum).
e. IGNITION AND ENGINE STARTER
switch OFF after 50% N1.
3. Engine and systems instruments Check.
4. Right PROP lever FEATHER.
5. GPU Disconnect.
6. Right PROP lever HIGH RPM.
7. INVERTER
switches
ON,
check
INVERTER lights OFF.
8. GEN switches RESET, then ON.
9. CONDITION levers As required.
10. Red anticollision light Reset.